AnyRidge and AnyOne share a brand prefix and nothing else that matters: AnyRidge uses a 5 degree Morse taper with a 2.3 mm internal hex, AnyOne an 11 degree internal hex with a 2.5 mm hex, so their components are not interchangeable. AnyRidge varies thread depth over a constant core; AnyOne varies the thread itself across three named variants.
Side by side
Rows appear only where at least one side has data. Where a value is not verified we say
so rather than leaving it blank.
Tapered fixture in which several fixture diameters share a single core diameter, so the drilling sequence is chosen by bone type rather than by fixture widthManufacturer-reported[1][3]
Tapered body with a straight coronal section, which MegaGen says makes insertion depth easier to controlManufacturer-reported[4]
Surface
XPEED — MegaGen describes a hydro-thermal incorporation of calcium ions producing a calcium titanate nanostructure on the surfaceManufacturer-reported[1]The XPEED surface is also the subject of independent laboratory and animal work.
Manufacturer documentation not located(The AnyOne Internal catalogue refers to an improved surface treatment without naming it in the copy we were able to read.)
Connection
Internal connection combining a 5-degree Morse taper with a 2.3 mm internal hex, the same size on every fixture diameterManufacturer-reported[3]
Internal hex with an 11-degree taper, 2.5 mm hex; a single prosthetic connection serves all fixture sizesManufacturer-reported[4]
Platform switching
The platform diameter is narrower than the widest thread diameter on every size, and MegaGen presents 0.5 to 1.0 mm subcrestal placement as the intended positionManufacturer-reported[3]
Platform diameter is Ø3.9 mm on every fixture from Ø4.0 upwards, so wider fixtures carry a narrower platform than their bodyManufacturer-reported[4]
Available diameters
Ten fixture diameters: Ø3.5, 4.0, 4.5, 5.0, 5.5, 6.0, 6.5, 7.0, 7.5 and 8.0 mm, built on core diameters of 3.3, 3.8, 4.0, 4.3 and 4.8 mmManufacturer-reported[3]
Regular thread in Ø3.5, 4.0, 4.5, 5.0, 6.0 and 7.0 mm; deep thread in Ø4.5, 5.5, 6.5, 7.5 and 8.0 mm; Special 7 mm in Ø4.5, 5.0, 6.0 and 7.0 mmManufacturer-reported[4]
Available lengths
7, 8.5, 10, 11.5, 13 and 15 mm; the 7 mm option is subject to local approval and the widest fixtures are not offered at 15 mmManufacturer-reported[3]
7.0, 8.0, 9.5, 11.0, 12.5 and 14.5 mm; the Ø6.0, Ø7.0 and Ø8.0 regular and deep-thread fixtures stop at 12.5 mmManufacturer-reported[4]
Tapered fixture in which several fixture diameters share a single core diameter, so the drilling sequence is chosen by bone type rather than by fixture widthManufacturer-reported[1][3]
MegaGen AnyOne
Tapered body with a straight coronal section, which MegaGen says makes insertion depth easier to controlManufacturer-reported[4]
Surface
MegaGen AnyRidge
XPEED — MegaGen describes a hydro-thermal incorporation of calcium ions producing a calcium titanate nanostructure on the surfaceManufacturer-reported[1]The XPEED surface is also the subject of independent laboratory and animal work.
MegaGen AnyOne
Manufacturer documentation not located(The AnyOne Internal catalogue refers to an improved surface treatment without naming it in the copy we were able to read.)
Connection
MegaGen AnyRidge
Internal connection combining a 5-degree Morse taper with a 2.3 mm internal hex, the same size on every fixture diameterManufacturer-reported[3]
MegaGen AnyOne
Internal hex with an 11-degree taper, 2.5 mm hex; a single prosthetic connection serves all fixture sizesManufacturer-reported[4]
Platform switching
MegaGen AnyRidge
The platform diameter is narrower than the widest thread diameter on every size, and MegaGen presents 0.5 to 1.0 mm subcrestal placement as the intended positionManufacturer-reported[3]
MegaGen AnyOne
Platform diameter is Ø3.9 mm on every fixture from Ø4.0 upwards, so wider fixtures carry a narrower platform than their bodyManufacturer-reported[4]
Available diameters
MegaGen AnyRidge
Ten fixture diameters: Ø3.5, 4.0, 4.5, 5.0, 5.5, 6.0, 6.5, 7.0, 7.5 and 8.0 mm, built on core diameters of 3.3, 3.8, 4.0, 4.3 and 4.8 mmManufacturer-reported[3]
MegaGen AnyOne
Regular thread in Ø3.5, 4.0, 4.5, 5.0, 6.0 and 7.0 mm; deep thread in Ø4.5, 5.5, 6.5, 7.5 and 8.0 mm; Special 7 mm in Ø4.5, 5.0, 6.0 and 7.0 mmManufacturer-reported[4]
Available lengths
MegaGen AnyRidge
7, 8.5, 10, 11.5, 13 and 15 mm; the 7 mm option is subject to local approval and the widest fixtures are not offered at 15 mmManufacturer-reported[3]
MegaGen AnyOne
7.0, 8.0, 9.5, 11.0, 12.5 and 14.5 mm; the Ø6.0, Ø7.0 and Ø8.0 regular and deep-thread fixtures stop at 12.5 mmManufacturer-reported[4]
The biggest differences
AnyRidge is built around its KnifeThread: MegaGen keeps the core diameter constant across several fixture diameters and varies how far the knife-shaped thread projects, so the drilling sequence is chosen by bone type rather than by fixture width. AnyOne takes the opposite approach and offers three thread designs — a regular thread, a deep thread for soft bone and a bevelled Special 7 mm fixture for irregular ridges — on a tapered body with a straight coronal section.
Design
AnyRidge lists ten fixture diameters from 3.5 to 8.0 mm, built on five core diameters, which makes the range smaller in practice than the number of sizes suggests. AnyOne covers 3.5 to 8.0 mm too, but splits that across its regular, deep and Special 7 mm thread families rather than offering every diameter in every form. Lengths run 7 to 15 mm on AnyRidge and 7.0 to 14.5 mm on AnyOne.
Material and surface
AnyRidge carries the XPEED surface, which MegaGen describes as a hydro-thermal incorporation of calcium ions producing a calcium titanate nanostructure — a chemically modified surface rather than a plain blasted and etched one. For AnyOne, the catalogue we worked from refers to an improved surface treatment without naming it, so we have left that field empty rather than assume it is the same treatment.
Prosthetic ecosystem
Both systems use one prosthetic connection across their whole diameter range, which is the feature they genuinely share. On AnyRidge that is a 5 degree Morse taper with a 2.3 mm internal hex; on AnyOne an 11 degree internal hex of 2.5 mm with a single 3.9 mm platform from 4.0 mm upwards. Because the two connections differ, a laboratory needs the system name and not just 'MegaGen'.
What may influence clinical selection
MegaGen positions AnyOne as a straightforward system for clinicians at any level of experience and AnyRidge as suitable across bone types with the drilling sequence chosen by density. A treatment plan naming only 'MegaGen' has not identified which implant was used, and since AnyRidge, AnyOne, BlueDiamond and ARi are separate designs rather than trim levels of one product, that is a question worth asking before treatment rather than after.
So which is better?
Neither is universally better, and any page telling you otherwise is selling something.
These are different designs with different trade-offs, and the right choice depends on the
bone available, the position in the mouth, the planned restoration, and what the treating
clinician is equipped and experienced to place and to service years from now.
That last point is easy to overlook and matters more than most specification
differences: components need to remain obtainable for as long as the implant is in place.
Regulatory record
US FDA 510(k) clearances held by each side, retrieved from the FDA's own database.
Clearances are held at brand level, so every system from the same brand shares this record.
MegaGen AnyRidge
via MegaGen
8
FDA 510(k) clearances
2011 – 2026
Filed by Megagen Implant Co., Ltd.
MegaGen AnyOne
via MegaGen
8
FDA 510(k) clearances
2011 – 2026
Filed by Megagen Implant Co., Ltd.
A clearance count is not a quality ranking, and the
larger number is not the better implant. A brand with more clearances usually
has a longer history or a broader component range. FDA "clearance" also is not FDA
"approval" — it means the device was accepted as substantially equivalent to one already
on the market, generally without a clinical trial. A blank here means we could not match
a filing with confidence, not that the brand lacks authorisation.
What these actually mean →
Sources
Numbers match the citations beside each claim above.