Straumann Standard
Also known as: S, Straumann Standard Implant, Straumann Tissue Level
The classic parallel-walled tissue-level implant in the Straumann Dental Implant System, with a 2.8 mm machined neck and the synOcta connection.
Quick facts
| Current status | Current. The Standard implant is one of the implant lines described in Straumann’s Dental Implant System Basic Information.Manufacturer-reported[1] |
|---|---|
| Implant level | Tissue level.Manufacturer-reported[1] |
| Body geometry | Parallel-walled endosteal body with a smooth machined neck section of 2.8 mm, intended for single-stage procedures in which the implant is not covered by soft tissue during healing.Manufacturer-reported[1] |
| Thread design | Thread pitch 1 mm on the ∅ 3.3 mm implant and 1.25 mm on all other diameters.Manufacturer-reported[1] |
| Apex design | Manufacturer documentation not located |
| Material | Roxolid with the SLActive or SLA surface, or titanium with an SLA surface.Manufacturer-reported[1] |
| Surface | SLActive or SLA.Manufacturer-reported[1] |
| Connection | synOcta — an internal Morse taper with an 8° cone and an octagon for repositioning prosthetic parts, on Regular Neck (RN, ∅ 4.8 mm) and Wide Neck (WN) platforms. Straumann also offers the Solid Abutment for this line.Manufacturer-reported[1] |
| Platform switching | Manufacturer documentation not located |
| Available diameters | Endosteal diameter ∅ 3.3, 4.1 and 4.8 mm.Manufacturer-reported[1] |
| Available lengths | S ∅ 3.3 mm RN: 8–16 mm. S ∅ 4.1 mm RN: 6–16 mm. S ∅ 4.8 mm RN: 6–14 mm. S ∅ 4.8 mm WN: 6–12 mm.Manufacturer-reported[1] |
Overview
Technology
Clinical positioning
What the manufacturer says this system is designed for. This is not the same thing as independent clinical evidence, which is set out separately below.
Clinical evidence
We have not yet completed a system-specific evidence review for Straumann Standard. Insufficient system-specific evidence How we grade evidence
Similar implant systems
Popular comparisons
The clearances below are held by Straumann at brand level and cover its implant range, not Straumann Standard specifically. We show them here because that is the level at which regulators actually issue them.
Regulatory record
Read this before drawing conclusions. A clearance or certificate means a device may legally be sold in a market. It is not a finding that the implant performs well, and it is not a comparison against other implants. In particular, FDA "clearance" is not FDA "approval" — clearance means the FDA accepted the device as substantially equivalent to one already on the market. What these actually mean →
FDA 510(k) clearance30 records
Cleared as substantially equivalent to a predicate device. Not an FDA approval, and not a finding of safety or effectiveness.
| Number | Device | Holder | Date |
|---|---|---|---|
| K252168 | Straumann® BLC Implants - Indication Widening | Institut Straumann AG | 2026-03-10 |
| K250294 | Straumann® RidgeFit Implants | Institut Straumann AG | 2025-08-12 |
| K241391 | Straumann® PURE Ceramic Implants | Institut Straumann AG | 2024-12-10 |
| K234049 | Straumann® BLC and TLC Implants - Line extension | Institut Straumann AG | 2024-03-20 |
| K230108 | Straumann® BLC and TLC Implants | Institut Straumann AG | 2023-09-14 |
| K223083 | Straumann SLActive labeling changes | Institut Straumann AG | 2023-06-22 |
| K211052 | Straumann RidgeFit Implants | Institut Straumann AG | 2021-07-08 |
| K210855 | Straumann BLX Implant System | Institut Straumann AG | 2021-06-21 |
| K202942 | Straumann 4 mm Short Implants | Straumann USA, LLC | 2021-02-08 |
| K200586 | Straumann TLX Implant System | Institut Straumann AG | 2020-08-20 |
| K191256 | Straumann BLX Ø3.5 mm Implants | Institut Straumann AG | 2019-12-27 |
| K191895 | Straumann Mini Implants | Institut Straumann AG | 2019-12-09 |
| K190662 | MRI Compatibility for Existing Straumann Dental Implant Systems | Straumann USA, LLC | 2019-06-17 |
| K180477 | Straumann PURE Ceramic Implant System | Institut Straumann AG | 2019-01-04 |
| K181703 | Straumann BLX Line Extension - Implants, SRAs and Anatomic Abutments | Institut Straumann AG | 2018-12-28 |
| K173961 | Straumann BLX Implant System | Institut Straumann AG | 2018-06-05 |
| K171784 | Straumann Dental Implant System | Straumann USA, LLC | 2018-01-19 |
| K171769 | Straumann PURE Ceramic Implants | Straumann USA, LLC (On Behalf of Institut Straumann Ag) | 2017-11-14 |
| K153758 | Straumann Bone Level Tapered Implants | Institut Straumann AG | 2016-03-23 |
| K150938 | Straumann® Dental Implant System ¿ Roxolid® SLA Implants | Straumann USA, LLC | 2015-07-24 |
| K140878 | STRAUMANN BONE LEVEL TAPERED IMPLANT | Straumann USA, LLC | 2014-08-20 |
| K130222 | STRAUMANN DENTAL IMPLANT SYSTEM | Straumann USA, LLC | 2013-04-29 |
| K123784 | STRAUMANN DENTAL IMPLANT SYSTEM | Straumann USA, LLC | 2013-04-10 |
| K111357 | STRAUMANN NARROW NECK CROSSFIT (NNC) 03.3MM DENTAL IMPLANT SYSTEM | Straumann USA | 2011-10-03 |
| K093027 | STRAUMANN RC TEMPORARY ABUTMENTS | Straumann USA | 2010-02-12 |
| K083550 | STRAUMANN DENTAL IMPLANT SYSTEM | Straumann USA | 2009-02-26 |
| K081419 | STRAUMANN DENTAL IMPLANT SYSTEM | Institut Straumann AG | 2009-02-20 |
| K060958 | STRAUMANN NARROW NECK IMPLANTS | Straumann USA | 2006-08-24 |
| K061176 | STRAUMANN DENTAL IMPLANTS | Institut Straumann AG | 2006-08-11 |
| K033984 | STRAUMANN DENTAL IMPLANT SYSTEM | Institut Straumann AG | 2004-06-30 |
Other1 record
Of 100 records we inspected, 93 are supplied sterile, 7 are supplied non-sterile and 0 do not state it. MRI safety labelling: Labeling does not contain MRI Safety Information (52); MR Conditional (48). A UDI listing records what the manufacturer declared about the device; it is not a clearance or an approval.
| Number | Device | Holder | Date |
|---|---|---|---|
| 1219 device records | — | Straumann | — |
Clearance records for Straumann were retrieved from the issuing authority's own database, not from the manufacturer's marketing material. We attribute a clearance to a brand only when the filing holder belongs to that brand's corporate family — third-party clearances for compatible components are excluded, because they belong to the company that made the component, not to Straumann.
Sources
Numbers match the citations beside each claim above.
Primary sources
- [1]Straumann Dental Implant System — Basic Information (702084/en) — Institut Straumann AG, 2025. Accessed 2026-07-21.